k6 warns: `The test has generated metrics with 100001 unique time series, which is higher than the suggested limit of 100000 and could cause high memory usage`.
IntermediateTroubleshootingk6 Load Testing
Answer
Likely causes → URLs with unique IDs (/orders/8f2c...) become the name and url tags, so each request creates new metric series.
Diagnose → Look for dynamic values in URLs and custom tags in the script.
Fix → Group URLs with a static name tag:
http.get(`${BASE}/orders/${id}`, { tags: { name: 'GET /orders/:id' } });
or use http.url template literals, which set the name tag automatically.
Prevent → Review scripts for high-cardinality tags, same as Prometheus label hygiene.
More on k6 Load Testing
k6 prints `WARN[0030] Insufficient VUs, reached 100 active VUs and cannot initialize more executor=constant-arrival-rate scenario=steady`.AdvancedCI fails with `ERRO[0602] thresholds on metrics 'http_req_duration' have been crossed` and exit code 99.BeginnerEvery request fails with `dial tcp: lookup checkout on 10.96.0.10:53: no such host`.BeginnerMany requests fail with `request timeout` after exactly 60 seconds.IntermediateThe test starts fine, then errors switch to `dial tcp 10.96.41.12:8080: connect: connection refused`.IntermediateThe k6 load generator logs `socket: too many open files`.Intermediate