The fast-burn page fired, yet the monthly SLO dashboard shows 99.96% against a 99.9% target. Is the alert wrong?
IntermediateTroubleshootingBurn-Rate Alerts & Alertmanager
Answer
Likely causes → Not wrong. Burn-rate alerts measure how fast the budget is being consumed right now, not whether the SLO is currently met. A 14.4x burn for an hour costs 2% of the monthly budget; left unchecked it would exhaust the budget in about 2 days.
Diagnose → Check the 1h error ratio and budget remaining side by side.
Fix → Nothing to fix in the alert; respond to the incident. Explain on the dashboard by showing burn rate next to budget remaining.
Prevent → Train on-call on burn rate vs budget; include both on the SLO dashboard.
More on Burn-Rate Alerts & Alertmanager
The burn-rate alert sits in `Pending` for the whole incident and never reaches `Firing`.IntermediateAfter a rollback fixed the incident, the page kept firing for another 50 minutes.IntermediateCheckout was completely down for 25 minutes and no burn-rate alert fired.AdvancedThe alert shows `Firing` in Prometheus, but Alertmanager's UI shows nothing.BeginnerAlertmanager won't load the new config: `undefined receiver "pager" used in route`.BeginnerAlertmanager logs `Notify for alerts failed` with `unexpected status code 404: no_service` for the Slack receiver.Beginner