The alert shows `Firing` in Prometheus, but Alertmanager's UI shows nothing.
BeginnerTroubleshootingBurn-Rate Alerts & Alertmanager
Answer
Likely causes → Prometheus is not configured to send to this Alertmanager (wrong alerting.alertmanagers config or service discovery), network policy blocks it, or Alertmanager is down.
Diagnose →
curl -s localhost:9090/api/v1/alertmanagers | jq '.data.activeAlertmanagers'
rate(prometheus_notifications_errors_total[5m])
prometheus_notifications_dropped_total
Fix → Fix the Alertmanager endpoints in the Prometheus config (in the operator: spec.alerting.alertmanagers), and allow traffic on port 9093.
Prevent → Alert on prometheus_notifications_errors_total and use a Watchdog heartbeat to an external dead man's switch.
More on Burn-Rate Alerts & Alertmanager
The burn-rate alert sits in `Pending` for the whole incident and never reaches `Firing`.IntermediateAfter a rollback fixed the incident, the page kept firing for another 50 minutes.IntermediateCheckout was completely down for 25 minutes and no burn-rate alert fired.AdvancedAlertmanager won't load the new config: `undefined receiver "pager" used in route`.BeginnerAlertmanager logs `Notify for alerts failed` with `unexpected status code 404: no_service` for the Slack receiver.BeginnerThe same burn-rate incident re-pages the on-call every 5 minutes.Intermediate