Interview Prep/SRE & Reliability/Burn-Rate Alerts & Alertmanager

The alert shows `Firing` in Prometheus, but Alertmanager's UI shows nothing.

BeginnerTroubleshootingBurn-Rate Alerts & Alertmanager
Answer

Likely causes → Prometheus is not configured to send to this Alertmanager (wrong alerting.alertmanagers config or service discovery), network policy blocks it, or Alertmanager is down.

Diagnose →

curl -s localhost:9090/api/v1/alertmanagers | jq '.data.activeAlertmanagers'
rate(prometheus_notifications_errors_total[5m])
prometheus_notifications_dropped_total

Fix → Fix the Alertmanager endpoints in the Prometheus config (in the operator: spec.alerting.alertmanagers), and allow traffic on port 9093.

Prevent → Alert on prometheus_notifications_errors_total and use a Watchdog heartbeat to an external dead man's switch.

All SRE & Reliability questions

More on Burn-Rate Alerts & Alertmanager