Interview Prep/SRE & Reliability/Burn-Rate Alerts & Alertmanager

The same burn-rate incident re-pages the on-call every 5 minutes.

IntermediateTroubleshootingBurn-Rate Alerts & Alertmanager
Answer

Likely causes → repeat_interval too short, or the alert's labels change (for example {{ $value }} placed in labels instead of annotations), creating a "new" alert each evaluation. Two tier alerts with different names but no grouping also produce separate pages.

Diagnose →

amtool --alertmanager.url=http://localhost:9093 alert query alertname=~"Checkout.*" -o extended

Check whether label values change between notifications.

Fix → Keep dynamic values in annotations only, group by [alertname, slo] or just [slo], set group_interval: 5m and repeat_interval: 4h for pages.

Prevent → Lint rules to forbid template expressions in labels.

All SRE & Reliability questions