Interview Prep/SRE & Reliability/Burn-Rate Alerts & Alertmanager

The 3-day ticket alert never fires, even during a slow multi-day burn.

AdvancedTroubleshootingBurn-Rate Alerts & Alertmanager
Answer

Likely causes → Prometheus retention is shorter than the window (for example --storage.tsdb.retention.time=2d), so [3d] only sees 2 days of data, or a recent restart without persistent storage wiped history.

Diagnose →

kubectl get prometheus -n monitoring -o jsonpath='{.items[0].spec.retention}'
prometheus_tsdb_lowest_timestamp_seconds

Fix → Increase retention beyond the longest SLO window (at least 30d for the budget) with persistent volumes, or evaluate long-window rules in Thanos Ruler or Mimir ruler against long-term storage.

Prevent → Document retention requirements in the SLO platform and alert if the lowest timestamp is newer than 30 days.

All SRE & Reliability questions

More on Burn-Rate Alerts & Alertmanager