You created a silence for a maintenance window, but the alert still pages.
BeginnerTroubleshootingBurn-Rate Alerts & Alertmanager
Answer
Likely causes → Matchers do not match the alert's actual labels (typo, wrong label name, exact match where a regex was needed), the silence expired, or it was created on one Alertmanager that is not clustered with the one sending.
Diagnose →
amtool --alertmanager.url=http://localhost:9093 silence query
amtool --alertmanager.url=http://localhost:9093 alert query --silenced
Compare the silence matchers with the alert labels.
Fix → Recreate with correct matchers, for example amtool silence add 'alertname=~"Checkout.*"' namespace=shop --duration=2h --comment="maintenance".
Prevent → Ensure Alertmanager replicas are clustered and use maintenance tooling that creates silences via the API with tested matchers.
More on Burn-Rate Alerts & Alertmanager
The burn-rate alert sits in `Pending` for the whole incident and never reaches `Firing`.IntermediateAfter a rollback fixed the incident, the page kept firing for another 50 minutes.IntermediateCheckout was completely down for 25 minutes and no burn-rate alert fired.AdvancedThe alert shows `Firing` in Prometheus, but Alertmanager's UI shows nothing.BeginnerAlertmanager won't load the new config: `undefined receiver "pager" used in route`.BeginnerAlertmanager logs `Notify for alerts failed` with `unexpected status code 404: no_service` for the Slack receiver.Beginner