Interview Prep/Monitoring & Observability/Alerting and On-Call Design

During a cascading outage with 200 firing alerts, the incident commander says "silence everything." What do you do?

AdvancedScenarioAlerting and On-Call Design
Answer

Situation read → The instinct is understandable, but blanket silences hide new failures and recovery signals.

What I'd do →

  1. Do not silence globally. Propose a targeted silence for alerts already acknowledged by the IC, using a matcher on incident or the known failing service set.
  2. Mark one dashboard or war-room view as the source of truth, so no one reads raw alert streams.
  3. Rely on grouping and inhibition rules to collapse noise (critical suppresses warning for the same cluster).
  4. Keep paging only for new symptoms outside the incident scope.
  5. Expire silences at a fixed time and review them in the post-incident review.

Why → You need recovery signals and any independent second failure to stay visible.

Interview tip → Say "silence by scope and time, never by 'everything'."

All Monitoring & Observability questions Roadmap: Monitoring & alerting

More on Alerting and On-Call Design