A "CPU above 90%" alert wakes someone at 3 a.m., but users saw no impact. What do you change?
BeginnerScenarioAlerting and On-Call Design
Answer
Situation read → A cause-based alert without evidence of user impact. High CPU alone is often just efficient use.
What I'd do →
- Remove the page. Keep CPU as a dashboard panel or a low-severity ticket alert with a long
for:(30m+). - Replace it with a symptom alert: latency or error ratio on the service.
- If CPU saturation does matter (throttling), alert on the effect:
rate(container_cpu_cfs_throttled_periods_total[5m]) / rate(container_cpu_cfs_periods_total[5m]) > 0.25. - Add the CPU panel to the service dashboard so it is a diagnosis step.
Why → Pages should reflect symptoms. Causes help you debug after you are already looking.
Interview tip → Say "I alert on symptoms, I dashboard causes."
More on Alerting and On-Call Design
Your on-call engineers receive 300 alerts a night and have started ignoring the pager. How do you fix it?IntermediateYou are asked to design alerting for a brand-new HTTP service from scratch. What do you alert on?BeginnerA new hire asks: "Should we page on symptoms or causes?" How do you answer with an example?BeginnerDesign burn-rate alerts for a 99.9% availability SLO over 30 days.AdvancedPayments and platform teams share one Prometheus and one Alertmanager. How do you route alerts to the right team and severity?IntermediateA database migration is scheduled for Saturday 02:00–04:00. How do you avoid pager noise without hiding real problems?Beginner