Situation read → An alert named HighLatency with no context costs ten minutes of orientation during an outage.

What I'd do → Standardize annotations:

  1. summary: one line with the impacted service and value ({{ $labels.service }} p99 is {{ $value | humanizeDuration }}).
  2. description: what it means for users, and likely causes.
  3. runbook_url: step-by-step diagnosis and mitigation.
  4. dashboard_url: pre-filtered Grafana link with var-service={{ $labels.service }}.
  5. Labels: severity, team, env.

Why → The goal is to move straight from page to diagnosis. A good runbook cuts mean time to mitigate more than a clever alert.

Interview tip → Mention that an alert without a runbook should not be allowed to page.