Interview Prep/Monitoring & Observability/Alerting and On-Call Design

How do you know if Prometheus or Alertmanager itself has silently died?

IntermediateScenarioAlerting and On-Call Design
Answer

Situation read → If the alerting pipeline fails, no alerts fire, and silence looks like health. You need an external heartbeat.

What I'd do →

  1. Add an always-firing Watchdog alert: expr: vector(1).
  2. Route it to a dead man's switch service (healthchecks.io, PagerDuty heartbeat, Opsgenie heartbeat, or a Grafana Cloud/Alertmanager heartbeat) with repeat_interval: 1m.
  3. If the heartbeats stop, that external service pages you.
  4. Also run a second, independent Prometheus that scrapes the first and alerts on up{job="prometheus"} == 0.

Why → The only reliable way to detect a dead alerter is something outside it that expects a regular signal.

Interview tip → The kube-prometheus-stack ships a Watchdog alert for exactly this purpose.

All Monitoring & Observability questions Roadmap: Monitoring & alerting

More on Alerting and On-Call Design