A disk in your RAID 1 array failed. How do you replace it without downtime?
IntermediateScenarioStorage, disks and filesystems
Answer
Situation read → Degraded mirror; swap and resync.
What I'd do →
cat /proc/mdstat # [U_] means degraded
sudo mdadm /dev/md0 --fail /dev/sdc --remove /dev/sdc
# physically replace the disk (hot-swap bay)
sudo sfdisk -d /dev/sdb | sudo sfdisk /dev/sdc # copy partition table if partitioned
sudo mdadm /dev/md0 --add /dev/sdc
watch cat /proc/mdstat
If the array is also the boot disk, reinstall the bootloader on the new disk.
Why → The array keeps serving from the healthy disk while it rebuilds.
Interview tip → Check smartctl -a on the surviving disk; a second failure during rebuild is the real risk.
More on Storage, disks and filesystems
You get paged at 3 AM: the root filesystem on a production server is at 98% and climbing. Walk through your response.BeginnerA new 200 GB EBS volume is attached to an EC2 instance. How do you make it usable and persistent across reboots?BeginnerThe `/var` LVM logical volume is nearly full and there is free space in the volume group. How do you grow it online?BeginnerThe volume group has no free space. You've been given a new disk. How do you add it to grow `/var`?IntermediateA cloud VM's root disk was enlarged from 30 GB to 80 GB in the console, but `df` still shows 30 GB. What do you do?BeginnerYou need to move a busy MySQL data directory from the root disk to a new, faster volume. Plan it.Intermediate