Interview Prep/SRE & Reliability/Grafana SLO Dashboards

The SLO dashboard's 1h burn-rate panel shows 9x, but the alert evaluated 15x at the same moment.

IntermediateTroubleshootingGrafana SLO Dashboards
Answer

Likely causes → The panel computes rate() itself with $__rate_interval or a different window and step, while the alert uses the recorded 1h ratio. Panel step alignment and min interval also change what is displayed.

Diagnose → Compare the panel query with the recording rule expression, and query the recorded series directly in Explore.

Fix → Make the panel query the same recorded series the alert uses (slo:sli_error:ratio_rate1h / 0.001).

Prevent → Single source of truth: dashboards and alerts both read recording rules.

All SRE & Reliability questions Roadmap: SRE & incident response