What is N+1 and N+2 redundancy for capacity?
BeginnerConceptCapacity, Load Testing & Chaos Engineering
Answer
N is the number of units needed to serve peak load. N+1 adds one spare so you survive losing any single unit; N+2 survives one planned outage (a deploy or maintenance) plus one unplanned failure at the same time. For zones: if you need 6 pods at peak across 3 AZs and want to survive losing an AZ, you need 3 pods per AZ (9 total), because the remaining two AZs must carry the full load.
More on Capacity, Load Testing & Chaos Engineering
What is capacity planning in SRE?BeginnerHow do you calculate how many instances you need?IntermediateWhat is the difference between load, stress, spike, soak and breakpoint testing?BeginnerWhat is k6 and why do SRE teams use it?BeginnerWrite a minimal k6 test with SLO thresholds.IntermediateWhat is the difference between open and closed workload models in load testing?Advanced