Interview Prep/Monitoring & Observability/Alerting and Alertmanager

An alert is `Firing` in Prometheus but nothing reaches Alertmanager

IntermediateTroubleshootingAlerting and Alertmanager
Answer

Likely causes → No alerting.alertmanagers configured, wrong address, or Operator alerting section points at the wrong Service/port.

Diagnose →

prometheus_notifications_alertmanagers_discovered
rate(prometheus_notifications_errors_total[5m])
rate(prometheus_notifications_dropped_total[5m])

Check Status → Runtime & Build Info for the Alertmanager list.

Fix → Point alerting.alertmanagers at the Alertmanager service (port 9093, or the named port web in the Operator).

Prevent → Alert on prometheus_notifications_alertmanagers_discovered < 1, and run a Watchdog alert to a dead man's switch.

All Monitoring & Observability questions Roadmap: Monitoring & alerting

More on Alerting and Alertmanager