Interview Prep/Monitoring & Observability/On-Call Integration & Alert Fatigue

What is alert fatigue and how do you measure it?

BeginnerProductionOn-Call Integration & Alert Fatigue
Answer

Alert fatigue is when on-call engineers become desensitised because most alerts are noise, so they miss or delay the real one. Measure it with:

  • Pages per shift and per night (target: a handful per week, near zero overnight).
  • % of pages that required action.
  • Time to acknowledge, trending up.
  • Number of alerts auto-resolved before anyone looked.

These come straight from PagerDuty/Opsgenie analytics. Share them in the weekly ops review.

All Monitoring & Observability questions Roadmap: Monitoring & alerting