How do you treat security and audit logs differently from application logs?

IntermediateProductionLog Pipelines
Answer
  • Never sampled or dropped.
  • Immutable storage (S3 Object Lock in compliance mode, WORM).
  • Separate access controls; application engineers cannot delete them.
  • Longer retention set by compliance (PCI DSS requires 1 year with 3 months immediately available).
  • Sent to the SIEM for detection rules.

Pipeline health for these streams gets its own alerts.