Interview Prep/GitOps & Argo CD/AppProjects, RBAC & SSO

What are sync windows?

IntermediateConceptAppProjects, RBAC & SSO
Answer

Project-level time windows that allow or deny syncs:

syncWindows:
  - kind: deny
    schedule: "0 22 * * *"
    duration: 8h
    applications: ["*-prod"]
    manualSync: true
    timeZone: "Asia/Kolkata"

deny blocks syncs during the window; allow permits syncs only inside it. manualSync: true lets humans sync during a deny window while blocking automated syncs. They are used for change freezes, business hours and festive-season freezes.