How do you design break-glass access when all access goes through SSO?
BeginnerProductionIdentity, Least Privilege & OIDC for CI
Answer
If the IdP is down, SSO is down. Keep a minimum of emergency access that does not depend on it:
- Two break-glass IAM users (or root in a few critical accounts) with hardware MFA keys stored in separate safes.
- Long random passwords kept in a sealed, audited vault or physical envelope.
- An alarm on any sign-in by these identities (EventBridge on
ConsoleLogin) that pages security. - Quarterly test login with a documented procedure, then rotate the password.
Use is always followed by a review explaining why.
More on Identity, Least Privilege & OIDC for CI
How do you design AWS OIDC trust for GitHub Actions so only production deploys can assume the prod role?IntermediateWhat are the common mistakes in OIDC trust policies for CI?AdvancedHow do you configure OIDC for GitLab CI to AWS?IntermediateHow do you get from "everyone has AdministratorAccess" to least privilege without breaking things?AdvancedWhat SCP guardrails do you apply across an AWS organisation?IntermediateHow do you implement just-in-time (JIT) privileged access for production?Intermediate