How does dead-lettering work in Service Bus?
IntermediateConceptServerless & integration (Functions, Logic Apps, Event Grid, Service Bus)
Answer
Messages move to the dead-letter subqueue when they exceed the maximum delivery count, expire, or are explicitly dead-lettered by the consumer. Monitor dead-letter counts, inspect the reason properties, fix the cause and resubmit messages with a tool or script.